All Categories

ASVG 500V SERIES

500V Advanced Static Var Generator (ASVG)

- Rated Frequency: 45Hz-63Hz
- Compensating Current: 90kvar
- Reactive Power Compensation Rate : ≥99%
- Machine Efficiency : ≥97%
- Installation: Rack-Mounted, Wall-Mounted

  • Overview
  • Specification
  • Appearance
  • Related Products

Product Overview

The ASVG is a novel current-type power quality management device. It adjusts the phase and amplitude of the output voltage on the inverter's AC side by real-time monitoring of the load current. This allows it to provide precise, simultaneous compensation for system reactive power, harmonics, and three-phase unbalanced currents. The ASVG is characterized by its strong comprehensive compensation capabilities, fast response time, and high cost-effectiveness, making it a better solution in the field of power quality management.

  

ͼƬ3.png

ASVG 500V Technical Specification

ASVG 500V Series

Altitude

<2000m (derated per GB/T 3859.2 above 2000m)

Ambient

Temperature

-10°C to+50°C (derated above 40℃)

Relative Humidity

≤ 90%, no condensation on surface at monthly min. temperature of 25°C

Pollution Level

Below Level III

Operating Voltage

AC500V

(-20%~+20%)

Operating Frequency

50Hz/60Hz(45Hz~63Hz)

Rated

Compensation

Capacity

90kvar

Power Grid Structure

3P3W,3P4W

Numbersin Parallel

Unlimited

System

Efficiency

≥97%

Switching Frequency

12.8kHz

Function Selection

Reactive Power,

Harmonics,

Reactive Power+Harmonics,

Harmonics+Reactive Power,

Harmonics+Unbalance,

Reactive Power+Unbalance,

Harmonics+Unbalance+Reactive Power

Reactive Power+Unbalance+Harmonics

Full Response Time

Reactive Power <10ms, Harmonic <40ms

Noise

≤65dB

Communication

2*RS485 Communication Ports(Supports WIFI)

Protection

Overload, Software/Hardware Overcurrent, Over/Undervoltage, Unbalance, Power Supply Fault, Overtemperature,Frequency Anomaly, Short Circuit Protection

Installation

Rack-Mounted, Wall-Mounted

Entry Line Method

Rear Inlet (Rack-Mounted), Top Inlet (Wall-Mounted)

Protection Level

IP20(IP54 is customizable)

ASVG 500V Product Appearance

Module Model

Models

Compensation

Capacity(kvar)

System Voltage(V)

Dimensions

Width*Depth*Height(mm)

Cooling System

AMS ASVG-0.5-90k/4L-W

90

500

839*500*328.5

Forced Air Cooling

Cabinet model

Models

Compensation Capacity (kvar)

System Voltage(V)

Dimensions

Width*Depth*Height(mm)

Cooling System

AMS ASVG-0.5-180k/4L-C

180

500

1250*1000*2200

Forced Air Cooling

AMSASVG-0.5-270k/4L-C

270

500

1250*1000*2200

Forced Air Cooling

AMS ASVG-0.5-360k/4L-C

360

500

1250*1000*2200

Forced Air Cooling

Note: -R(Rack)/ -W(Wall)/ -C(Cabinet)

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000