Advanced Static Var Generator Plus(ASVG Plus)
-Theory: Adopting a DSP + CPLD digital control core, three-level topology technology, and advanced algorithms for reactive power, harmonic, and three-phase unbalanced detection to achieve comprehensive power quality management.
-Operating frequency: 50Hz/60Hz (45Hz~63Hz).
-Power grid structure: Three-phase three-wire, three-phase four-wire.
-External current sampling channel: Two current sampling channel.
-Operation Mode: Reactive power, Unbalance, Harmonic.
-Compensation mode: Low voltage sampling low voltage compensation, high voltage sampling low voltage compensation, reactive power component.
-Neutral line filtering capability: The neutral line filtering capability is three times that of the phase filtering capability.
- Overview
- Specification
- Apparence
- Related Products
Product Overview
The high-end enhanced static var generator (ASVG PLUS) is an upgraded version of the enhanced static var generator. This device can achieve 3 times the zero line current output capability and also has an EMC filter standard built-in. It can comprehensively and accurately compensate for reactive power, harmonics, and three-phase unbalanced currents in the system simultaneously. The high-end enhanced static var generator (ASVG PLUS) has stronger compensation capability and higher reliability.

Technical Specification
| 380V Series | |
| Altitude | <2000m, Usage should be de-rated according to the international standard IEC 3859-2 for altitudes above 2000 meters. | 
| Ambient Temperature | -10°C to +50°C (derated above 40 ℃) | 
| Relative Humidity | ≤ 90%, monthly minimum temperature 25 ℃, no condensation on the surface. | 
| Pollution Level | Below Level III | 
| Operating Voltage | AC380V (-20%~+20%) | 
| Operating Frequency | 50Hz/60Hz (45Hz~63Hz) | 
| Rated Compensation Capacity | 75kvar, 100kvar | 
| Power Grid Structure | Three-phase three-wire, Three-phase four-wire | 
| Numbers in Parallel | Unlimited | 
| System Efficiency | ≥97% | 
| Switching Frequency | 16kHz | 
| Function Selection | Reactive Power, Harmonics, Reactive Power + Harmonics, Harmonics + Reactive Power Harmonics + Unbalance, Reactive Power + Unbalance, Harmonics + Unbalance + Reactive Power, Reactive Power + Unbalance + Harmonics; Self-Aging Reactive Power; | 
| Full Response Time | <40ms | 
| Neutral Line Filtering Capability | The neutral line filtering capability is three times that of the phase filtering capability. | 
| EMC Standard | IEC 61000-4 | 
| Noise | ≤60dB | 
| Communication | 2*RS485 Communication Ports (Supports GPRS/WIFI) | 
| Protection | Overload, software/hardware over current, power grid over voltage/under voltage, power failure, over-temperature, frequency abnormality, short circuit protection | 
| Installation | Rack-Mounted, Wall-Mounted | 
| Entry Line Method | Rear Inlet (rack-mounted), Top Inlet (wall-mounted) | 
| Protection Level | IP20 | 
Model Definition
| Module Model | ||||
| Models | Compensation Capacity (kvar) | System Voltage (V) | Dimensions Width * Depth * Height (mm) | Cooling System | 
| AMS ASVG PLUS-0.4-75k/4L-R | 75 | 400 | 500*550*240 | Forced Air Cooling | 
| AMS ASVG PLUS-0.4-100k/4L-R | 100 | 400 | 500*550*240 | Forced Air Cooling | 
| Cabinet Model | ||||
| Models | Compensation Capacity (kvar) | System Voltage (V) | Dimensions Width * Depth * Height (mm) | Cooling System | 
| AMS ASVG PLUS-0.4-200k/4L-C | 200 | 400 | 1000*1000*2200 | Forced Air Cooling | 
| AMS ASVG PLUS-0.4-250k/4L-C | 250 | 400 | 1000*1000*2200 | Forced Air Cooling | 
| AMS ASVG PLUS-0.4-300k/4L-C | 300 | 400 | 1000*1000*2200 | Forced Air Cooling | 
| AMS ASVG PLUS-0.4-400k/4L-C | 400 | 400 | 1000*1000*2200 | Forced Air Cooling | 
 
     EN
    EN
    
   
                       
                      